Container Farm:40 ft Vegetable Container Farm Hydroponic Oat and Wheat Fodder Programme
PRODUCT OVERVIEW
Hydroponic Oat and Wheat Fodder is one of the faster-turning crops in the container: 8 - 10 days from transplant, 2,400 - 3,200 kg per cycle and 36 - 45 cycles a year. The insulated envelope and fresh-air system stop summer heat and winter cold from interrupting the rhythm.
Tier heights and aisle width are set for standing work, so harvesting, replanting and cleaning avoid stooping and reduce fatigue over long shifts.
Rotating with wheat balances supply and suits farms building their own fresh-fodder line.
Remote sites and institutional kitchens use the unit to fix unreliable leafy supply; Hydroponic Oat and Wheat Fodder is harvestable in 8 - 10 days without long-haul deliveries.
CROP AND OUTPUT DATA
Variety | Hydroponic Oat and Wheat Fodder (Fodder) |
Growing cycle (transplant to harvest) | 8 - 10 days |
Unit weight | marketable weight |
Plants per cycle | approx. 3,300 - 5,800 |
Yield per cycle | 2,400 - 3,200 kg |
Cycles per year | 36 - 45 |
Annual output (estimate) | 86,400 - 144,000 kg |
Propagation | Direct seeding |
Crop difficulty | Easy |
Figures follow the 40 ft standard container baseline with about five growing tiers. Yield per cycle and annual output are estimates; actual results vary with tier count, light recipe, CO2 level and crop management.
KEY ADVANTAGES
· The unit can be shared with other leafy varieties on a weekly rotation for a more flexible product mix.
· 3,300 - 5,800 plants per cycle and 2,400 - 3,200 kg per cycle make output plannable against contracts.
· Per-tier LED recipes give more uniform leaf colour, plant shape and head weight.
· Rotation and zoning reduce disease pressure and chemical inputs.
· About five tiers lift output per square metre to roughly five times open-field levels.
· 36 - 45 cycles a year keep the same unit producing continuously without a seasonal break.
· Rated Easy in difficulty and run from process cards, the crop is workable by general staff.
· Batch records of temperature, EC, pH and light trace each harvest back to a specific tier.
CONTAINER CONFIGURATION
Footprint | 12.19 x 2.44 x 2.90 m (40 ft ISO container) |
Growing system | Approx. 5 tiers, hydroponic or aeroponic |
Scale per cycle | 3,300 - 5,800 plants |
Temperature | 18 - 24 °C, set per variety |
Relative humidity | 60 - 75% |
CO2 concentration | 800 - 1,200 ppm |
Lighting | LED recipe, dimmable per tier |
Nutrient solution | Closed loop with automatic EC and pH control |
Energy reference | 0.8 - 1.2 kWh per kg of fresh greens; electricity about 60 - 70% of operating cost |
Control and monitoring | PLC, touchscreen HMI, remote monitoring and alarms |
Delivery | Pre-commissioned at the factory, set and connected on site |
CLIMATE AND CONTROL
The controller stores recipes by variety - temperature, humidity, photoperiod, irrigation frequency and nutrient targets - called up as a set. Changing crops loads a new recipe while batch history is retained.
Nutrient solution runs from the tank through pumps and manifolds to each tier and returns via filtration, disinfection and inline monitoring. EC and pH are corrected automatically against the recipe, removing manual mixing drift.
CULTIVATION AND SCHEDULING
After harvest the room is cleaned and sanitised and the return line flushed, with downtime held under a day so the 36 - 45-cycle annual plan is not eroded.
The standard schedule assumes a 40 ft unit with about five tiers: plant one batch and harvest one batch each week, giving 36 - 45 Hydroponic Oat and Wheat Fodder cycles a year. Adjust to order structure and harvest labour.
DELIVERY, TRAINING AND SERVICE
The unit transports and relocates as a standard container, so a lease expiry or site change does not strand the capital.
Crop changes and expansion include recipe support, covering cycle validation and density recommendations for new varieties.
FREQUENTLY ASKED QUESTIONS
How many units can one operator manage?
Under a standard schedule, one operator can cover daily rounds, nutrient top-up and harvest coordination for two to three units, with extra hands at harvest peaks.
Is pre-cooling needed after harvest?
Leafy greens should be cooled to 4 - 8 °C quickly after harvest; an optional pre-cooling zone in the unit shortens the gap between cutting and storage.
Can the operating data be exported?
The controller stores temperature, humidity, CO2, EC, pH and light by batch, exportable for order audits and origin documentation.
Why is the Hydroponic Oat and Wheat Fodder cycle faster than in the field?
Inside the unit, temperature, humidity, CO2 and light are held at recipe values with no stress stall, so Hydroponic Oat and Wheat Fodder reaches harvest in about 8 - 10 days - more than half the open-field time.
CONTACT AND DATA NOTES
Hangzhou Hengyu Intelligent Technology Co., Ltd. designs, builds and delivers complete container farms. Share your site conditions, target varieties and daily volume, and we will return a layout, a crop schedule and an energy estimate. Figures in this document use the 40 ft standard container (about five growing tiers) as the baseline and are estimates; output varies with tier count, light recipe, CO2 level and crop management, and is not a performance guarantee.